VENT SAFETY SHUTOFF SYSTEM
This heater must be properly connected to a venting system. This
heater is equipped with a vent safety shutoff system.
Warning:
Operation of this heater, when not connected to a prop-
erly installed and maintained venting system or tamper-
ing with the vent safety shutoff system, can result in
carbon monoxide (CO) poisoning and possible death.
This appliance needs fresh air for safe operation and must be
installed so there are provisions for adequate combustion and
ventilation air.
This room heater is equipped with a vent safety switch. The
vent safety switch will cause gas flow to the pilot to “shut off”
due to improper venting or a blocked flue.
If the vent safety switch continues to “shut off” the gas flow to
the pilot a qualified service person must be contacted to
inspect for improper venting, blockage in the vent pipe or the
vent safety switch for being defective.
REVERSIBLE VERTICAL OR HORIZONTAL DRAFT DIVERTER
DRAFT DIVERTER CAN BE EITHER A VERTICAL
VENT OR HORIZONTAL VENT
Figure 4
This room heater has a reversible draft diverter. The draft diverter
is installed in the vertical position at the factory. Please use the
following steps to change the draft diverter from the vertical
position to the horizontal position.
1. Remove L280 vent safety switch from the draft diverter.
2. Inside your yellow instruction envelope will be a 1 1/2" x
2 1/4" (38mm x 51mm) vent safety switch hole cover plate
and two (2) 1/2" screws for attachment of vent safety switch
hole cover plate to the draft diverter. Attach vent safety switch
hole cover plate over hole on the draft diverter from which the
L280 vent safety switch was removed.
3. Remove two (2) screws at bottom of draft diverter and lift
upward to remove draft diverter from the draft diverter plate.
Rotate draft diverter into the horizontal position and slide
back into the draft diverter plate. Attach two (2) screws into
bottom of the draft diverter.
4. Remove vent safety switch hole knockout and two (2) knock-
outs for screws on opposite side of draft diverter.
5. Attach L280 vent safety switch to the draft diverter.
6. Repositioning of the draft diverter is completed.
THERMOSTAT OPERATION
Thermostat Operation
To turn on burner, rotate dial knob toward setting number 7. To
shut down burner, rotate dial knob toward number 1.
The dial numbers 1 through 7 correspond to 50° (10°C) through
90°F (32°C). This is the temperature at the bulb thermostat not the
room temperature. The owner is advised to determine the particu-
lar heat setting that is desired for comfort, as heating requirements
are different for every owner.
Attention: If no heat is desired, turn the gas control knob to the
PILOT position.